Parts Manual for PHL668U

Click Here for Exploded Diagram and Parts List to find the Location ID of the part you're after. 

If it doesn't show up in our search system, email steve@appliancespares.nz for pricing & availability. There may be a new code or its not a common item and needs to be list

Error Code Error / Cause Solution
ER03 Continuous key press, control is switching
OFF after 10 sec. Water or part on glass. Clean ceramic glass.
ER13 Controller defect, internal error. Replace controller.
ER21 Power switch OFF due to over temperature. Let hob cool down
remove pots/pans.
ER22 Key detection unit defect. Replace controller.
ER25
Secondary voltage of power supply too high
(prim. > 300V) (incorrectly connected) Display
error message as long as power is available.
(approximately 5-10 seconds)
Connect mains correctly.
ER26 Relay voltage too high in OFF state. Replace controller.
ER40
Over voltage protection (PTC) is active, low
voltage at Microprocessor. (2.0V – 2.8V)
1. Incorrectly connected.
2. Over temperature.
1. Connect mains
correctly.
2. Disconnect appliance
from mains for a
minimum of 20 seconds.